英文MSDS库
当前位置:化工字典 > 英文MSDS
Name:
1 4-Dioxane anhydrous 99.0% AcroSeal
Synonym:
p-Dioxane; Diethylene ether; Diethylene dioxide; Diox; Glycol ethylene ether
CAS:
123-91-1
Section 1 - Chemical Product
MSDS Name:1 4-Dioxane anhydrous 99.0% AcroSeal
Synonym:p-Dioxane; Diethylene ether; Diethylene dioxide; Diox; Glycol ethylene ether
Section 2 - COMPOSITION, INFORMATION ON INGREDIENTS
CAS# Chemical Name emsds EINECS#
123-91-1
Hazard Symbols: XN F
Risk Phrases:

Section 3 - HAZARDS IDENTIFICATION
EMERGENCY OVERVIEW
Highly flammable. May form explosive peroxides. Irritating to eyes and respiratory system. Limited evidence of a carcinogenic effect.
Repeated exposure may cause skin dryness or cracking.Hygroscopic.
Potential Health Effects
Eye:
Causes eye irritation.
Skin:
May cause skin irritation. May be absorbed through the skin in harmful amounts. Prolonged and/or repeated contact may cause irritation and/or dermatitis.
Ingestion:
May cause gastrointestinal irritation with nausea, vomiting and diarrhea. May cause central nervous system depression, characterized by excitement, followed by headache, dizziness, drowsiness, and nausea. Advanced stages may cause collapse, unconsciousness, coma and possible death due to respiratory failure.
Inhalation:
Effects may be delayed. Inhalation of high concentrations may cause central nervous system effects characterized by nausea, headache, dizziness, unconsciousness and coma. Causes respiratory tract irritation. Inhalation of vapor may cause severe respiratory tract irritation. Olfactory fatigue may occur.
Chronic:
May cause liver and kidney damage. May cause cancer according to animal studies.

Section 4 - FIRST AID MEASURES
Eyes: In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Get medical aid.
Skin:
In case of contact, flush skin with plenty of water. Remove contaminated clothing and shoes. Get medical aid if irritation develops and persists. Wash clothing before reuse.
Ingestion:
Possible aspiration hazard. If swallowed, do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical aid.
Inhalation:
If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical aid.
Notes to Physician:

Section 5 - FIRE FIGHTING MEASURES
General Information:
As in any fire, wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion. Use water spray to keep fire-exposed containers cool. Flammable liquid and vapor. May form explosive peroxides. May accumulate static electrical charges, and may cause ignition of its own vapors.
Approach fire from upwind to avoid hazardous vapors and toxic decomposition products. Vapors are heavier than air and may travel to a source of ignition and flash back. Vapors can spread along the ground and collect in low or confined areas.
Extinguishing Media:
Use water spray, dry chemical, carbon dioxide, or alcohol-resistant foam.

Section 6 - ACCIDENTAL RELEASE MEASURES
General Information: Use proper personal protective equipment as indicated in Section 8.
Spills/Leaks:
Absorb spill with inert material (e.g. vermiculite, sand or earth), then place in suitable container. Avoid runoff into storm sewers and ditches which lead to waterways. Clean up spills immediately, observing precautions in the Protective Equipment section. Remove all sources of ignition. Use a spark-proof tool. Flush spill area with water. Provide ventilation. A vapor suppressing foam may be used to reduce vapors.

Section 7 - HANDLING and STORAGE
Handling:
Wash thoroughly after handling. Remove contaminated clothing and wash before reuse. Use spark-proof tools and explosion proof equipment. Loosen closure cautiously before opening. Avoid contact with eyes, skin, and clothing. Empty containers retain product residue, (liquid and/or vapor), and can be dangerous. Take precautionary measures against static discharges. If peroxide formation is suspected, do not open or move container. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose empty containers to heat, sparks or open flames. Use only with adequate ventilation. Avoid breathing vapor or mist.
Storage:
Store in a tightly closed container. Store in a cool, dry, well-ventilated area away from incompatible substances.
Flammables-area. After opening, purge container with nitrogen before reclosing. Periodically test for peroxide formation on long-term storage. Addition of water or appropriate reducing materials will lessen peroxide formation. Containers should be dated when opened and tested periodically for the presence of peroxides. Should crystals form in a peroxidizable liquid, peroxidation may have occurred and the product should be considered extremely dangerous. In this instance, the container should only be opened remotely by professionals. All peroxidizable substances should be stored away from heat and light and be protected from ignition sources.

Section 8 - EXPOSURE CONTROLS, PERSONAL PROTECTION
Engineering Controls:
Facilities storing or utilizing this material should be equipped with an eyewash facility and a safety shower. Use adequate general or local exhaust ventilation to keep airborne concentrations below the permissible exposure limits.
Personal Protective Equipment Eyes: Wear chemical goggles.
Skin:
Wear appropriate protective gloves to prevent skin exposure.
Clothing:
Wear nitrile-latex gloves, apron, and/or clothing.
Wear appropriate protective clothing to prevent skin exposure.
Respirators:
A respiratory protection program that meets OSHAs 29 CFR 1910.134 and ANSI Z88.2 requirements or European Standard EN 149 must be followed whenever workplace conditions warrant a respirators use.

Section 9 - PHYSICAL AND CHEMICAL PROPERTIES

Physical State: Liquid
Color: clear, colorless
Odor: ethereal odor
pH: Not available.
Vapor Pressure: 29 mm Hg @ 20 deg C
Viscosity: 0.012cP @ 25 deg C
Boiling Point: 101 deg C
Freezing/Melting Point: 12 deg C
Autoignition Temperature: 180 deg C ( 356.00 deg F)
Flash Point: 12 deg C ( 53.60 deg F)
Explosion Limits, lower: 2.0%
Explosion Limits, upper: 22.0%
Decomposition Temperature:
Solubility in water: Soluble.
Specific Gravity/Density: 1.0300 g/cm3
Molecular Formula: C4H8O2
Molecular Weight: 88.11

Section 10 - STABILITY AND REACTIVITY
Chemical Stability:
Prolonged exposure to air and sunlight may form unstable peroxides.
Tends to form explosive peroxides; especially when anhydrous. Under normal storage conditions, peroxidizable compounds can form and accumulate peroxides which may explode when subjected to heat or shock. This material is most hazardous when peroxide levels are concentrated by distillation or evaporation.
Conditions to Avoid:
Light, ignition sources, excess heat, electrical sparks.
Incompatibilities with Other Materials:
Strong oxidizing agents, strong acids.
Hazardous Decomposition Products:
Carbon monoxide, irritating and toxic fumes and gases, carbon dioxide.
Hazardous Polymerization: Has not been reported
Section 11 - TOXICOLOGICAL INFORMATION
RTECS#:
CAS# 123-91-1: JG8225000 LD50/LC50:
CAS# 123-91-1: Draize test, rabbit, eye: 100 mg Severe; Draize test, rabbit, eye: 100 mg/24H Moderate; Inhalation, mouse: LC50 = 37 gm/m3/2H; Inhalation, rat: LC50 = 46 gm/m3/2H; Oral, mouse: LD50 = 5300 mg/kg; Oral, rabbit: LD50 = 2 gm/kg; Oral, rat: LD50 = 4200 mg/kg; Skin, rabbit: LD50 = 7600 uL/kg.
Carcinogenicity:
1,4-Dioxane - Not listed by ACGIH, IARC, NIOSH, NTP, or OSHA.
Other:
See actual entry in RTECS for complete information.

Section 12 - ECOLOGICAL INFORMATION
Ecotoxicity:
Fish: Bluegill/Sunfish: LC50 = >10,000mg/L; 96 Hr.; Static conditions, 23 degrees CWater flea Daphnia: EC50 =163 mg/L; 48 Hr.; Static Condition, 20-21 degrees C
Section 13 - DISPOSAL CONSIDERATIONS
Dispose of in a manner consistent with federal, state, and local regulations.

Section 14 - TRANSPORT INFORMATION

IATA
Shipping Name: Dioxane
Hazard Class: 3
UN Number: 1165
Packing Group: II
IMO
Shipping Name: DIOXANE
Hazard Class: 3
UN Number: 1165
Packing Group: II
RID/ADR
Shipping Name: Dioxane
Hazard Class: 3
UN Number: 1165
Packing group:

Section 15 - REGULATORY INFORMATION

European/International Regulations
European Labeling in Accordance with EC Directives
Hazard Symbols: XN F
Risk Phrases:
R 11 Highly flammable.
R 19 May form explosive peroxides.
R 36/37 Irritating to eyes and respiratory system.
R 40 Limited evidence of a carcinogenic effect.
R 66 Repeated exposure may cause skin dryness or
cracking.
Safety Phrases:
S 9 Keep container in a well-ventilated place.
S 16 Keep away from sources of ignition - No
smoking.
S 36/37 Wear suitable protective clothing and
gloves.
S 46 If swallowed, seek medical advice immediately
and show this container or label.
WGK (Water Danger/Protection)
CAS# 123-91-1: 2
United Kingdom Occupational Exposure Limits

United Kingdom Maximum Exposure Limits

Canada
None of the chemicals in this product are listed on the DSL/NDSL list.
CAS# 123-91-1 is not listed on Canadas Ingredient Disclosure List.
Exposure Limits
CAS# 123-91-1: OEL-AUSTRALIA:TWA 25 ppm (90 mg/m3);Skin
OEL-AUSTRIA:TWA 50 ppm (180 mg/m3);Skin
OEL-BELGIUM:TWA 25 ppm (90 mg/m3);Skin
OEL-DENMARK:TWA 10 ppm (36 mg/m3);Skin
OEL-FINLAND:TWA 25 ppm (90 mg/m3);STEL 40 ppm (13 mg/m3);Skin
OEL-FRANCE:TWA 10 ppm (35 mg/m3);STEL 40 ppm (140 mg/m3);CAR
OEL-GERMANY:TWA 50 ppm (180 mg/m3);Skin;Carcinoge
OEL-HUNGARY:STEL 10 mg/m3;Skin;Carcinogen
OEL-JAPAN:TWA 10 ppm (36 mg/m3);Skin;Carcinogen
OEL-THE NETHERLANDS:TWA 50 ppm (180 mg/m3);Skin
OEL-THE PHILIPPINES:TWA 100 ppm (360 mg/m3);Skin
OEL-POLAND:TWA 10 mg/m3
OEL-RUSSIA:TWA 10 ppm;STEL 10 mg/m3;Skin
OEL-SWEDEN:TWA 25 ppm (90 mg/m3);STEL 50 ppm;Skin;CAR
OEL-SWITZERLAND:TWA 25 ppm (90 mg/m3);STEL 50 ppm;Skin
OEL-TURKEY:TWA 100 ppm (360 mg/m3);Skin
OEL-UNITED KINGDOM:TWA 25 ppm (90 mg/m3);STEL 100 ppm;Skin
OEL IN BULGARIA, COLOMBIA, JORDAN, KOREA check ACGIH TLV
OEL IN NEW ZEALAND, SINGAPORE, VIETNAM check ACGI TLV
US FEDERAL
TSCA
CAS# 123-91-1 is not listed on the TSCA inventory.
It is for research and development use only.