英文MSDS库
当前位置:化工字典 > 英文MSDS
Name:
3-Picolyl chloride hydrochloride 99%
Synonym:
3-(Chloromethyl)pyridine hydrochloride; Pyridine, 3-chlorormethyl-, hydrochlorid
CAS:
6959-48-4
Section 1 - Chemical Product
MSDS Name:3-Picolyl chloride hydrochloride 99%
Synonym:3-(Chloromethyl)pyridine hydrochloride; Pyridine, 3-chlorormethyl-, hydrochlorid
Section 2 - COMPOSITION, INFORMATION ON INGREDIENTS
CAS# Chemical Name emsds EINECS#
6959-48-4 3-Picolyl chloride hydrochloride 99 230-150-4
Hazard Symbols: XN
Risk Phrases: 22 33

Section 3 - HAZARDS IDENTIFICATION
EMERGENCY OVERVIEW
Harmful if swallowed. Danger of cumulative effects.Cancer suspect agent.Hygroscopic (absorbs moisture from the air).Toxic.
Potential Health Effects
Eye:
Causes eye irritation. May cause conjunctivitis and corneal inflammation.
Skin:
Causes skin irritation. Substance is readily absorbed through the skin.
Ingestion:
Harmful if swallowed. Causes gastrointestinal irritation with nausea, vomiting and diarrhea.
Inhalation:
Causes irritation of the mucous membrane and upper respiratory tract.
Chronic:
Animal studies have reported the development of tumors.

Section 4 - FIRST AID MEASURES
Eyes: Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid immediately.
Skin:
Get medical aid immediately. Flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes.
Ingestion:
Never give anything by mouth to an unconscious person. Get medical aid immediately. Do NOT induce vomiting. If conscious and alert, rinse mouth and drink 2-4 cupfuls of milk or water.
Inhalation:
Get medical aid immediately. Remove from exposure and move to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Notes to Physician:

Section 5 - FIRE FIGHTING MEASURES
General Information:
As in any fire, wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion.
Extinguishing Media:
Use water spray, dry chemical, carbon dioxide, or appropriate foam.

Section 6 - ACCIDENTAL RELEASE MEASURES
General Information: Use proper personal protective equipment as indicated in Section 8.
Spills/Leaks:
Clean up spills immediately, observing precautions in the Protective Equipment section. Sweep up, then place into a suitable container for disposal. Avoid generating dusty conditions. Provide ventilation.

Section 7 - HANDLING and STORAGE
Handling:
Wash thoroughly after handling. Remove contaminated clothing and wash before reuse. Use with adequate ventilation. Do not get in eyes, on skin, or on clothing. Keep container tightly closed. Do not ingest or inhale. Use only in a chemical fume hood. Do not breathe dust.
Storage:
Store in a cool, dry place. Keep containers tightly closed. Store protected from moisture.

Section 8 - EXPOSURE CONTROLS, PERSONAL PROTECTION
Engineering Controls:
Facilities storing or utilizing this material should be equipped with an eyewash facility and a safety shower. Use adequate ventilation to keep airborne concentrations low.
Exposure Limits CAS# 6959-48-4: Personal Protective Equipment Eyes: Wear safety glasses and chemical goggles if splashing is possible.
Skin:
Wear appropriate protective gloves and clothing to prevent skin exposure. Rubber and plastic gloves should not be relied upon to prevent skin contact.
Clothing:
Wear appropriate protective clothing to minimize contact with skin. Rubber and plastic gloves should not be relied upon to prevent skin contact.
Respirators:
Wear a NIOSH/MSHA or European Standard EN 149 approved full-facepiece airline respirator in the positive pressure mode with emergency escape provisions.

Section 9 - PHYSICAL AND CHEMICAL PROPERTIES

Physical State: Powder
Color: yellow-white
Odor: None reported.
pH: Not available.
Vapor Pressure: Not available.
Viscosity: Not available.
Boiling Point: Not available.
Freezing/Melting Point: 141.00 - 144.00 deg C
Autoignition Temperature: Not applicable.
Flash Point: Not applicable.
Explosion Limits, lower: Not available.
Explosion Limits, upper: Not available.
Decomposition Temperature: Not available.
Solubility in water: Not available.
Specific Gravity/Density: Not available.
Molecular Formula: C6H6ClN.HCl
Molecular Weight: 164.04

Section 10 - STABILITY AND REACTIVITY
Chemical Stability:
Stable under normal temperatures and pressures.
Conditions to Avoid:
Incompatible materials, strong oxidants, exposure to moist air or water.
Incompatibilities with Other Materials:
Moisture, strong bases, strong oxidizing agents.
Hazardous Decomposition Products:
Hydrogen chloride, nitrogen oxides, carbon monoxide, carbon dioxide, chloride fumes.
Hazardous Polymerization: Will not occur.

Section 11 - TOXICOLOGICAL INFORMATION
RTECS#:
CAS# 6959-48-4: US7000000 LD50/LC50:
CAS# 6959-48-4: Oral, mouse: LD50 = 316 mg/kg; Oral, rat: LD50 = 316 mg/kg.
Carcinogenicity:
3-Picolyl chloride hydrochloride - Not listed by ACGIH, IARC, or NTP.
Other:
See actual entry in RTECS for complete information.

Section 12 - ECOLOGICAL INFORMATION
Other No information available.

Section 13 - DISPOSAL CONSIDERATIONS
Dispose of in a manner consistent with federal, state, and local regulations.

Section 14 - TRANSPORT INFORMATION

IATA
Not regulated as a hazardous material.
IMO
Not regulated as a hazardous material.
RID/ADR
Not regulated as a hazardous material.

Section 15 - REGULATORY INFORMATION

European/International Regulations
European Labeling in Accordance with EC Directives
Hazard Symbols: XN
Risk Phrases:
R 22 Harmful if swallowed.
R 33 Danger of cumulative effects.
Safety Phrases:
S 24/25 Avoid contact with skin and eyes.
WGK (Water Danger/Protection)
CAS# 6959-48-4: No information available.
Canada
None of the chemicals in this product are listed on the DSL/NDSL list.
CAS# 6959-48-4 is not listed on Canadas Ingredient Disclosure List.
US FEDERAL
TSCA
CAS# 6959-48-4 is not listed on the TSCA inventory.
It is for research and development use only.